Maintenance & Seasonal

Roof Ventilation in Ontario: How Many Roof Vents Does Your Attic Need? (2026)

Emad AlikhanpourRoofing & Exterior Specialist•November 21, 2026• 13 min read
Roof Ventilation in Ontario: How Many Roof Vents Does Your Attic Need? (2026)
On this page

Key takeaways

  • Roof ventilation carries off the water vapour that leaks up from the house before it condenses on the cold roof deck. NRCan calls it the second line of defence, after air sealing.
  • NBC 2020, which Ontario's 2024 Code adopts, asks for vent area of at least 1/300 of the insulated ceiling area (1/150 on low slopes), with at least a quarter high and a quarter low. Vent makers split it half and half.
  • A 1,200 sq ft attic needs 576 square inches of vent: 288 at the top, which is about 16 feet of ridge vent or six 50 square inch roof vents.
  • On a hip roof with all four slopes at one pitch, the ridge is only the house's length minus its width, so a compact two-storey can have too little ridge for a ridge vent to do the job.
  • Use one kind of exhaust per attic. Air Vent says never mix them, NRCan says whirlybirds are no more effective than capped vents, and it advises against electric attic fans.

Push the attic hatch open on a frigid January morning and shine a light at the underside of the roof. If every nail tip poking through the deck wears a white cap of frost, your roof ventilation is losing a race it was never meant to run alone. Roof ventilation is the slow draft that enters at the soffits, runs up the underside of the roof deck and leaves near the ridge, and in an Ontario winter its job is to carry off the moisture that leaks up from the house before it settles on cold wood.

Most ventilation advice stops at a picture of a box vent. This guide does the arithmetic: what the Building Code asks for, how many roof vents a real attic needs, when a ridge vent fits and when it cannot, and which vents to leave on the shelf. At Sherak, we install asphalt shingle roofs across York Region, Simcoe, Kawartha and the GTA, and on a re-roof the vents are part of the same job.

Ventilation is also the second half of the fix, not the first. Our guide to preventing ice damming in Ontario explains why a row of new vents rarely cures an ice dam. This one is about getting the vents themselves right.

What Does Roof Ventilation Do in an Ontario Winter?

Roof ventilation moves outdoor air through the attic, in at the soffits and out near the ridge, so the water vapour that leaks up from the house leaves before it condenses on the cold roof deck. In summer the same airflow carries off heat. It cannot stop the air leaks themselves, and it does not cure ice dams.

The National Building Code of Canada 2020, which Ontario's 2024 Building Code adopts, explains in a note to Article 9.19.1.1 why attics are still vented. Controlling the moisture that air leakage and vapour diffusion carry into an attic is necessary to limit deterioration, the note says, and given that imperfections normally exist in vapour barriers and air barrier systems, venting of attic or roof spaces is generally still required. The ceiling below is never perfectly sealed, so the attic needs a way to dry out.

Natural Resources Canada's Keeping the Heat In sets the order. After air sealing, it calls attic ventilation "your second line of defence against the water vapour", and it is plain about the limits: vents "will not prevent condensation and will not solve the problems created by air leakage." A perfectly vented attic still frosts up if a bathroom fan is blowing into it.

How Many Roof Vents Does Your Attic Need? (Ontario Code Math)

How Many Roof Vents Do I Need? The 1/300 Rule, Worked Through

Divide the insulated ceiling area by 300 for the total vent area the Code asks for, then put half of it near the ridge and half at the soffits. A 1,200 sq ft attic needs 4 square feet, or 576 square inches, of vent: 288 at the top, which is six 50 square inch roof vents.

Article 9.19.1.2 sets the number. The unobstructed vent area must be at least 1/300 of the insulated ceiling area, and at least 1/150 where the roof slope is less than 1 in 6 or the roof is built with roof joists. The vents can be roof, eave or gable-end types in any combination, spread uniformly on opposite sides of the building, with at least 25 percent of the required openings at the top of the space and at least 25 percent at the bottom. Ontario adopts this national text through its own regulation, so on new work your municipal building department has the final word.

  1. Measure the ceiling, not the roof. The figure is the insulated ceiling under the attic, which on a simple house is its footprint. Overhangs and the slope of the roof do not count.
  2. Divide by 300, or by 150 for a roof flatter than 2 in 12 or one built on roof joists, then multiply by 144 for square inches.
  3. Split it. The Code's floor is a quarter high and a quarter low. Vent makers and NRCan aim for half and half, and the ventilation calculator in Canplas's technical manual says a home requires an equal amount of intake and exhaust.
  4. Divide the top half by the vent's net free area, the open area its maker publishes, never the size of the box.

Worked through for common attic sizes, at 1/300 with an even split. The ridge vent columns are in square inches per lineal foot of vent:

Attic, sq ftVent, sq inAt top, sq inRidge vent at 18.3, ftRidge vent at 12.75, ft50 sq in vents
1,00048024013.118.85
1,20057628815.722.66
1,50072036019.728.28
2,00096048026.237.610
2,5001,20060032.847.112

The two ridge vent columns are the two ends of one Ontario maker's range. Canplas, the Barrie company behind Duraflo vents, rates its moulded WeatherPRO ridge vent at 18.3 square inches per lineal foot, and its catalogue lists roll vents down to 12.75. Same attic, over 40 percent more ridge, which is why the vent belongs on a quote by product name. The last column is not an estimate either: for the four attic sizes in its own calculator, Canplas's count of 50 square inch roof vents matches ours.

Will a Ridge Vent Fit? Gable Roofs Versus Hip Roofs

On a gable roof, almost always, because the ridge runs the full length of the house. On a hip roof with all four slopes at one pitch, the ridge is only the house's length minus its width, and the slot has to stop short of both ends, so a compact two-storey can have too little ridge to vent its attic.

The chart works that through for three example footprints, drawn to one scale. Each attic gets its 1/300 vent area split evenly, the ridge vent is rated at Canplas's 18.3 square inches a foot, and the slot stays closed for 12 inches at each end of the ridge, as Canplas's installation guide asks. As a gable, the 36 by 32 foot two-storey has 34 feet of ridge to cut. As a hip, it has 2.

Look at the bungalow too. Its hip ridge takes the vent it needs with about 4 and a half inches to spare, which is no margin at all: switch to a 12.75 square inch roll vent and the same attic needs 25.3 feet of slot against the 18 the roof can give. On a roof like that, the honest answer is a row of static roof vents set just below the ridge, sized to carry the whole top half on their own.

Aerial view of a two-storey brick house with a grey shingled hip roof, a short ridge and a row of black static box roof vents set just below it
Illustration: on a hip roof with a short ridge, a row of static roof vents set just below the ridge carries the exhaust.
Will a ridge vent fit? Three example footprints as gable and hip roofs (Sources: NBC 2020 Article 9.19.1.2, 1/300 split evenly; Canplas WeatherPRO ridge vent 18.3 sq in per foot, 50 sq in roof vent, 12 in closed at each ridge end)
Ridge vent, 18.3 sq in a foot, to lengthRidge vent the attic would needRoof vent, 50 sq in, to scaleTwo-storey: 36 x 32 ft, 1,152 sq ft of ceilingNeeds 553 sq in of vent, 276 sq in of it at the top: 15.1 ft ofridge vent, or 6 roof vents.Gable roofRidge 36 ft, 34 ft can beslottedFits: 15.1 ft of vent, 18.9 ftto spareHip roofRidge 4 ft, 2 ft can be slottedShort by 13.1 ft: 6 roof ventsinsteadBungalow: 48 x 28 ft, 1,344 sq ft of ceilingNeeds 645 sq in of vent, 323 sq in of it at the top: 17.6 ft ofridge vent, or 7 roof vents.Gable roofRidge 48 ft, 46 ft can beslottedFits: 17.6 ft of vent, 28.4 ftto spareHip roofRidge 20 ft, 18 ft can beslottedFits: 17.6 ft of vent, 0.4 ftto spareLong bungalow: 60 x 30 ft, 1,800 sq ft of ceilingNeeds 864 sq in of vent, 432 sq in of it at the top: 23.6 ft ofridge vent, or 9 roof vents.Gable roofRidge 60 ft, 58 ft can beslottedFits: 23.6 ft of vent, 34.4 ftto spareHip roofRidge 30 ft, 28 ft can beslottedFits: 23.6 ft of vent, 4.4 ftto spareA hip roof here has all four slopes at one pitch, so its ridgeis the house's length less its width. The slot stays closed 1 ftat each end of the ridge.Exhaust is not mixed: where the ridge falls short, every squareinch at the top goes to roof vents, set just below the ridge.
Will a ridge vent fit? Three example footprints as gable and hip roofs (Sources: NBC 2020 Article 9.19.1.2, 1/300 split evenly; Canplas WeatherPRO ridge vent 18.3 sq in per foot, 50 sq in roof vent, 12 in closed at each ridge end)
HouseCeiling areaVent area neededAt the topRidge vent neededGable ridge that can be slottedHip ridge that can be slottedRoof vents instead
Two-storey, 36 x 32 ft1,152 sq ft553 sq in276 sq in15.1 ft34 ft, fits2 ft, too short6
Bungalow, 48 x 28 ft1,344 sq ft645 sq in323 sq in17.6 ft46 ft, fits18 ft, fits7
Long bungalow, 60 x 30 ft1,800 sq ft864 sq in432 sq in23.6 ft58 ft, fits28 ft, fits9

Not sure what your roof can take?

We will quote the roof and its ventilation together, free and with no obligation.

Get a Free Quote

Ridge Vent, Box Vents or Whirlybirds: Which Roof Vents Are Best?

Where the ridge is long enough, a baffled ridge vent, because it exhausts along the whole peak, the highest line in the attic. Where it is not, static roof vents set just below the ridge. NRCan says whirlybirds are no more effective than capped vents, and it advises against electric attic fans.

Exhaust ventHow it worksPublished openingBest onWatch for
Ridge ventA 2 inch slot along the peak, covered by the vent and cap shingles12.75 to 18.3 sq in a foot (Canplas range)Gable roofs, long hip ridgesA short ridge; NRCan wants it baffled against wind, water and snow
Static roof vent (box vent)A louvred cap over a square cut-out near the peak48 to 130 sq in each (Canplas static vents)Hip roofs, short ridgesMore holes, each one flashed into the shingles
Wind turbine (whirlybird)A head that spins in the windSized by the maker's own chartRarely the best pickNRCan: no suction, no better than a capped vent
Gable louvreA louvred opening in an end wallVaries by sizeGables where the roof stays uncutCounts as exhaust, so it does not pair with a ridge vent
Power attic fanAn electric fan in the roof or a gableRated in airflow, not open areaNot recommendedNRCan: pulls house air into the attic

Are whirlybirds better than roof vents? NRCan answers it in one line: "Wind-driven, revolving roof vents do not create suction and are no more effective than other types of capped vents." A turbine is also the one moving part on the roof, and Canplas sells a replacement top for turbines that have started squeaking. Lomanco, which makes the Whirlybird, sizes them by its own chart, two 12 inch turbines for an attic of 1,000 to 1,500 square feet, rather than by open area.

Electric attic fans get a firmer no. NRCan advises against them because they can draw more air than the intake supplies: "This will actually pull house air into the attic, resulting in greater heat loss and moisture accumulation. They are also prone to failure, noise production and increased energy use."

The downsides of a ridge vent are the price of its advantages. It needs intake below it, it needs enough ridge, and it has to be built to shed weather. Canplas's instructions call for a slot 2 inches wide, an inch either side of the peak, and it builds baffles into its vent to turn back wind-driven rain and snow. Ask which ridge vent is on your quote, and how it is baffled.

Why One Attic Gets One Kind of Exhaust Vent

Because two kinds of exhaust on one attic can work against each other. One of them can start acting as an intake, so the air takes a shortcut between the two, parts of the attic are bypassed, and rain or snow can be drawn in through the vent that has turned into an intake.

That is Air Vent's position, and it does not hedge: it is never OK to mix two different types of attic exhaust vents over a common attic. Air Vent groups exhaust into five kinds, ridge vents, wind turbines, roof louvres, gable louvres and power vents, and says each uses the wind differently. The Code itself allows roof, eave and gable vents in any combination. The no-mixing rule is the vent makers' advice on making that combination work.

Two cases are worth naming. The first is a gable-ended house with louvres in both end walls that gets a ridge vent on a re-roof: the louvres are exhaust too. The second is the hip roof from the chart, where it is tempting to run whatever ridge vent fits and top it up with box vents. Pick one. If a re-roof moves an attic to a ridge vent, the old roof vents should come off and their holes be decked over and shingled, not left in place as a second exhaust.

Old asphalt shingles being stripped from a roof on Brant Street East in Orillia, with roofing shovels resting on the slope and torn courses near the chimney
Tear-off on Brant Street East, Orillia, March 2025. We replaced the decking under these shingles in full and upgraded the ventilation in the same two days.

Air In: Roof Vents Only Work If the Soffit Breathes

An exhaust vent can only let out what the intake lets in. A ridge vent over a solid, painted or insulation-packed soffit has little air to move, which is why the Code puts at least a quarter of the vent area at the bottom of the attic and the vent makers put half there.

Article 9.19.1.3 protects the path between the two. It wants at least 63 mm between the top of the insulation and the underside of the roof sheathing. At the eaves, where baffles hold the insulation back, it wants an air space of at least 25 mm that is large enough for the required venting, and the baffles must extend at least 50 mm above the top of the insulation. Ceiling insulation must not restrict the flow of air through roof vents or any part of the attic.

How much vented soffit a roofline needs is worked out in our soffit and fascia guide, and on a house with no overhang to vent, its section on vented fascia covers what takes over at the edge. On District Avenue in Vaughan in May 2025, we replaced the soffit around the whole house with a vented aluminum system to improve the attic's ventilation, with aluminum-clad fascia and new seamless eavestrough on the same job. When the intake is the problem, that is a soffit and fascia job, not a roof job.

Frost on the Nails: Attic Condensation in January

Frost on the nail tips and the underside of the deck after a cold snap means moist house air is reaching the attic. NRCan expects some frost. Heavy buildup, 10 mm or more, is the cue to check that the vents are there and not blocked with insulation, and because the vapour comes up from the house, to look for the leaks too.

Look during or just after a cold snap, which is when NRCan says condensation shows up as frost in a cold climate, and look hardest above the bathrooms, around the attic hatch, and wherever a pipe, duct or wire comes up through the ceiling. NRCan's line on the source is short: moisture can come from inside the house, carried into the attic as water vapour by air leakage.

A bathroom fan that ends in the attic, or whose duct has come apart, delivers shower steam straight to the cold deck. The Code does not allow a fan to exhaust into an attic, and our article on a bathroom fan dripping water works out how much water one shower sends up the duct. That frost has a second act. On the first mild day it melts, and the water can reach the ceiling below, which looks like a roof leak with no rain in the forecast.

More roof vents are the tempting fix, and the wrong first one. Seal the leaks, then make sure the vents you already have are clear and balanced, which is the same order that stops ice dams.

Frost crystals on the tips of roofing nails poking through the plywood roof sheathing inside an attic, lit by a flashlight above blown insulation
Illustration: frost on the nail tips under the roof deck, the January sign that house air is reaching the attic.

When Should Roof Ventilation Be Fixed? During the Re-roof

During a roof replacement, if you can. With the shingles off, a ridge slot can be cut, old vents pulled and their holes decked over, and the deck checked while it is open. The warranties on the shingles we install also exclude damage caused by inadequate ventilation, so the new roof depends on getting it right.

When we re-roofed a house on Brant Street East in Orillia on March 27 and 28, 2025, the wood decking under the old shingles had deteriorated. We replaced all of it, and installed new, upgraded ventilation in the same two days. That is what a re-roof makes possible: the deck is open, the crew is already on the roof, and the vents go on with the new shingles.

The warranty side is set out in our guide to the best asphalt shingles for Ontario: the warranty excludes damage caused by inadequate ventilation and expects the venting to meet code for total area, distributed between the ridge and the eaves. On our roof replacement cost breakdown, ventilation is one of the lines that separates a low quote, with the old vents reused, from one with intake and exhaust balanced to the code ratio. Ask every quote to name the exhaust and the intake, with the area worked out.

We back the work with a 10 year workmanship warranty, carry $5 million in liability insurance, and take 10 percent of the price only once you are satisfied. If you are planning a re-roof, or you have found frost in the attic, get a free quote and tell us what you are seeing. We are based in Gormley and work across York Region, Simcoe, Kawartha and the GTA, from Whitchurch-Stouffville to Orillia.

Sherak Ltd, Head Office

12275 Woodbine Avenue, Gormley, ON L0H 1G0

Phone: +1 905 490 8800

Email: info@sherak.ca

Re-roofing, or chasing attic frost?

We will quote the roof and its ventilation together, free and with no obligation. 10 year workmanship warranty and $5 million liability insurance.

Get a Free Quote

Frequently asked questions

How many roof vents do I need for a 1,200 sq ft house?
At 1/300, a 1,200 square foot attic needs 4 square feet of vent, which is 576 square inches. Half of it, 288 square inches, goes near the ridge: six 50 square inch roof vents or about 16 feet of an 18.3 square inch ridge vent. The other 288 goes in at the soffits. On a roof flatter than 2 in 12, double all of it.
Are whirlybirds better than roof vents?
No. Natural Resources Canada says wind-driven, revolving roof vents do not create suction and are no more effective than other types of capped vents. A turbine also adds a moving part to the roof, and like any exhaust it should not be mixed with a ridge vent or box vents over the same attic.
Should a ridge vent go all the way to the end of the roof?
The vent can, but the slot under it should not. Canplas's installation guide keeps 12 inches of sheathing closed at both ends of the ridge, covered to prevent infiltration, and runs the vent itself to within half an inch of the ridge end. On a hip roof those closed ends come off a ridge that is already short.
Is it okay to have gable vents with a ridge vent?
Air Vent says no. Gable louvres are one of its five kinds of exhaust, and two kinds of exhaust over a common attic short-circuit each other, with the risk of weather being drawn in through the one that turns into an intake. Pick one: either the ridge vent or the louvres serve as the exhaust for that attic, not both.
Can rain or snow get in through roof vents?
Wind-driven rain and fine snow can, which is why good vents are baffled. NRCan wants ridge vents fitted with baffles to deflect wind and keep out water and snow, and Canplas builds internal baffles into its vents to turn both back. Mixed exhaust raises the risk, because a vent that becomes an intake pulls weather in with the air.
Do you put shingles over a ridge vent?
Yes, on a shingle-over ridge vent. The vent is nailed along the peak over the slot, and ridge cap shingles are nailed over the vent, centred between its raised baffle walls, with nails at least 2 inches long in Canplas's instructions.
Does my attic need roof vents if it has soffit vents?
Yes. NBC 2020 Article 9.19.1.2 requires at least 25 percent of the required vent openings at the top of the attic as well as at the bottom, so soffit vents alone have nowhere to send the air. The top openings can be a ridge vent, roof vents or gable-end vents, ideally one kind rather than a mix.

Share this article

EA

Written by

Emad Alikhanpour

Roofing & Exterior Specialist

Emad has 15 years of hands-on experience across roofing and every exterior service Sherak offers, from shingle and metal roofs to siding, eavestroughs, soffit and fascia, and custom flashing.

15 years in the trade · Roofing and exterior services

View profile

Reader reviews

Loading reviews...

Leave a review

Your rating

Ready to start your project?

Request a free, no obligation quote today, or call us for emergency roof repair.

Call NowFree Quote